IES TM-30 vs CRI: What Is the Difference in LED Color Rendering?

Neutral white LED retail lighting illuminating clothing, leather handbags, suede footwear and cosmetics displays.

IES TM-30 and CRI both evaluate LED colour rendering, but they use different methods. CRI Ra averages eight general colour samples, while TM-30 evaluates 99 samples and provides additional information about colour fidelity, gamut and hue shifts.

IES TM-30 vs CRI: 4000K LED track lighting illuminating garments in a contemporary European fashion boutique.

1. What Is CRI in LED Lighting?

CRI (Colour Rendering Index) measures how accurately a light source reproduces colours compared with a reference illuminant.

The most commonly specified value is CRI Ra, calculated as the arithmetic average of eight general colour rendering indices, R1 to R8.

MetricDescription
R1–R8Eight general colour evaluation samples
RaArithmetic average of R1–R8
ScaleCommonly expressed from 0 to 100
Higher RaIndicates greater average colour fidelity to the reference

A higher Ra generally indicates closer average colour matching. However, it does not describe how accurately every individual colour is rendered.

What is R9?

R9 represents saturated red and is not included in the Ra calculation.

This distinction matters in retail lighting, particularly when illuminating red garments, leather products, cosmetics, wood finishes and other materials with important red colour components.

An LED can have a high Ra value but a comparatively low R9 value. Therefore, buyers should check R9 separately when saturated-red rendering is important.

CRI remains widely used because it is straightforward to understand and commonly included in LED product specifications. Its main limitation is that a single average value cannot fully describe the colour shifts produced by a light source.

LED colour rendering test showing saturated red textile samples and a colour reference chart for CRI and R9 evaluation.

2. What Is IES TM-30?

IES TM-30 is a technical method developed by the Illuminating Engineering Society to provide a more detailed evaluation of light-source colour rendition.

Unlike CRI Ra, which averages eight general colour samples, TM-30 uses 99 Colour Evaluation Samples (CES) covering a broader range of colours.

The method compares the appearance of these samples under a test light source with their appearance under an appropriate reference illuminant.

TM-30 provides several numerical and graphical outputs rather than relying on one average score.

Main TM-30 metrics

MetricFull nameWhat it measures
RfFidelity IndexAverage colour fidelity relative to the reference
RgGamut IndexRelative change in overall colour gamut area
CVGColour Vector GraphicVisual representation of hue and chroma shifts
Hue-bin data16 hue-angle binsColour changes across different hue regions

These metrics provide complementary information. For projects where accurate product presentation matters, reviewing the full TM-30 results is more useful than looking at one number alone.

Illustrative arrangement of 99 physical colour evaluation samples used in IES TM-30 colour rendition assessment.

3. TM-30 Rf vs CRI Ra: What Is the Difference?

Rf and Ra both evaluate average colour fidelity, but they use different sample sets and calculation methods. Their numerical values are not directly interchangeable.

ComparisonCRI RaTM-30 Rf
Evaluation samples8 general samples99 colour evaluation samples
Main purposeAverage colour fidelityAverage colour fidelity
Calculation methodCIE colour rendering methodIES TM-30 method
Colour-space approachTraditional CIE methodCAM02-UCS-based approach
Additional hue informationNot included in Ra itselfAvailable through additional TM-30 outputs
Typical reportingOne general indexRf, Rg and additional graphical information

For example, an LED with Ra 95 and another with Rf 95 should not automatically be considered equivalent.

The two values come from different evaluation systems. A meaningful comparison requires the full test results and the relevant project requirements.

IES TM-30 infographic explaining the difference between Rf colour fidelity and Rg relative gamut area.

Why can two LEDs with the same CRI look different?

Two LED products can have the same Ra value but produce visibly different colour results.

Ra is an average, so different combinations of colour shifts can produce the same final score.

One LED may reproduce certain reds and greens differently from another, even when both have an identical Ra value.

TM-30 provides additional information by evaluating more colour samples and showing how colour appearance changes across different hue regions.

For product selection, the spectral power distribution (SPD), TM-30 results and actual visual assessment can help explain differences that a single CRI number cannot show.

4. What Do TM-30 Rf and Rg Mean?

Rf and Rg describe different aspects of colour rendition. They should not be interpreted as interchangeable quality scores.

Rf: Colour Fidelity

Rf measures how closely the colours of the evaluation samples are reproduced compared with the reference illuminant.

  • A higher Rf indicates greater average colour fidelity.
  • Rf = 100 represents a match to the reference for the evaluated samples.
  • A lower Rf indicates greater average colour differences from the reference.

However, higher fidelity does not automatically mean a light source will be preferred in every application. Some lighting designs may intentionally seek a particular colour appearance rather than the closest possible match to a reference.

Rg: Relative Gamut Area

Rg describes the relative area of the colour gamut produced by the test source compared with the reference.

Rg valueGeneral interpretation
Rg = 100Overall gamut area is approximately the same as the reference
Rg > 100Overall gamut area is larger than the reference
Rg < 100Overall gamut area is smaller than the reference

An Rg value above 100 does not mean that every colour becomes more saturated. Similarly, an Rg value below 100 does not mean that every colour becomes less saturated.

Rg is an overall measure. It does not identify which specific hue regions have increased or decreased chroma.

This is why the Colour Vector Graphic and hue-bin information are important when interpreting TM-30 results.

Conceptual IES TM-30 Colour Vector Graphic showing 16 equal hue-angle bins and differences in chroma.

5. What Does the TM-30 Colour Vector Graphic Show?

The Colour Vector Graphic (CVG) provides a visual representation of how the test light source changes colour appearance relative to the reference.

It divides colour information into 16 hue-angle bins, helping lighting professionals examine:

  • Which hue regions show changes in chroma.
  • Whether certain colour regions become more or less saturated.
  • Where hue shifts occur.
  • Whether colour changes are balanced or concentrated in particular regions.

Rf and Rg summarise overall performance. The CVG provides additional information about the pattern of colour changes.

Two light sources can have similar Rf and Rg values but different hue-specific results. The graphic helps reveal these differences.

For projects where product colour is critical, do not evaluate a TM-30 report using Rf and Rg alone.

6. CRI vs TM-30: Which Is More Useful for Retail Lighting?

Both methods are useful for LED product evaluation. The appropriate choice depends on the merchandise, visual requirements and level of detail needed in the lighting specification.

Retail applicationWhat to evaluateWhy it matters
Fashion storesRa, R9, Rf, Rg and CVGGarment colours, fabrics and product details need consistent presentation
Cosmetics storesRa, R9 and TM-30 dataMakeup shades and skin-related colours require careful evaluation
Shoe storesRa, R9 and hue-specific resultsLeather, suede and coloured materials may respond differently to lighting
SupermarketsRa and application-specific colour dataFood appearance can be affected by the spectral characteristics of lighting
Jewellery storesRa, Rf, Rg and visual evaluationMetal finishes, gemstones and coloured surfaces need to be assessed under the intended lighting
General circulation areasProject-specified CRI requirementsColour rendering requirements may differ from those of product display areas

There is no single Rf or Rg target that is automatically suitable for every retail project.

The specification should reflect the merchandise, material finishes, intended visual appearance and reference conditions used for evaluation.

For fashion retail, it is particularly useful to check the appearance of key garment colours under the proposed luminaires before final approval.

LED spectral power distribution measurement using a spectroradiometer in a professional optical testing laboratory.

7. CRI, TM-30 and Full Spectrum: What Is the Difference?

CRI, TM-30 and full spectrum are related to light quality, but they describe different things.

TermWhat it describesWhat it does not tell you by itself
CRI RaAverage colour fidelity using eight general samplesFull spectral distribution or detailed hue shifts
IES TM-30Colour rendition using 99 samples and additional metricsComplete visual comfort or every aspect of spectral quality
Full spectrumA description commonly used for the spectral distribution of a light sourceA universally defined CRI or TM-30 performance level
SPDSpectral Power Distribution across wavelengthsVisual preference or overall lighting quality without further evaluation

A light source can achieve a high CRI or TM-30 score without having a perfectly continuous spectrum.

Similarly, describing an LED as full spectrum does not automatically establish its colour fidelity or guarantee a particular Rf or Rg result.

To understand the spectral characteristics of an LED, request its SPD curve. To evaluate colour rendition, review CRI and, where relevant, the TM-30 report.

These are complementary forms of information, not interchangeable labels.

8. What Should Buyers Request from an LED Lighting Manufacturer?

A product datasheet containing only a CRI value may not provide enough information for projects where colour appearance is critical.

Before approving an LED track light, downlight or other retail luminaire, buyers should consider requesting:

  1. CRI Ra: Confirm the general colour rendering index.
  2. R9: Check saturated-red rendering separately from Ra.
  3. TM-30 report: Request Rf, Rg and the relevant graphical results when available.
  4. SPD curve: Review the spectral power distribution rather than relying only on a full-spectrum label.
  5. CCT and Duv: Confirm the correlated colour temperature and chromaticity deviation.
  6. Test conditions: Check that the report refers to the exact LED configuration, CCT and operating conditions being specified.
  7. Sample evaluation: Compare actual products under the intended installation conditions.

For multi-store retail projects, it is also important to maintain consistent LED specifications across production batches and replacement orders.

A report for one LED configuration should not be assumed to represent every CCT, wattage or product version.

9. How BREE LIGHTING Approaches Colour Rendering in Retail Projects

At BREE LIGHTING, colour rendering is one of the factors considered when selecting LED track lights and other commercial luminaires for retail environments.

For fashion stores, boutiques and product display areas, the lighting specification should consider more than the CRI value alone.

The evaluation should take account of:

  • The merchandise and materials being illuminated.
  • The required colour temperature.
  • The distribution and beam angle of the luminaires.
  • The relationship between accent lighting and ambient lighting.
  • Available CRI, R9 and TM-30 test information.
  • The appearance of products under actual project conditions.

For projects where colour accuracy is important, buyers and lighting designers should request the relevant test reports for the exact LED configuration and assess product samples before confirming the final specification.

The aim is to select lighting that presents merchandise consistently and meets the visual requirements of the store.

Neutral white LED retail lighting illuminating clothing, leather handbags, suede footwear and cosmetics displays.

10. Frequently Asked Questions

TM-30 provides a more detailed evaluation of colour rendition than CRI Ra because it uses 99 colour evaluation samples and includes additional information such as gamut and hue-specific changes. CRI remains useful for basic product comparison and specifications.

TM-30 offers a broader evaluation method, but CRI is still widely used in product datasheets and project specifications. Buyers may request both values to support comparison and documentation.

No. Both relate to average colour fidelity, but they use different calculation methods and sample sets. Their numerical values should not be directly compared.

Rg 102 indicates that the overall gamut area is approximately 2% larger than that of the reference. It does not mean that every colour is 2% more saturated.

No. Ra is calculated from R1 to R8 and does not include R9. If saturated-red rendering is important, request the R9 value separately.

No. TM-30 evaluates colour rendition. It does not certify that an LED has a continuous or complete spectral distribution. Request the SPD curve to examine spectral characteristics.

TM-30 is particularly useful when colour differences between products, materials or finishes are important. Whether it should be a formal requirement depends on the project’s visual objectives and testing requirements.

Conclusion

CRI Ra remains a useful starting point for evaluating LED colour rendering, but it provides only an average based on eight general colour samples.

IES TM-30 provides a broader assessment through 99 colour evaluation samples, Rf, Rg, hue-bin information and the Colour Vector Graphic.

For retail lighting projects, the practical approach is to review the relevant colour-rendering data together with the SPD curve, product configuration and actual visual performance.

Do not select an LED luminaire based on one number alone. The right specification should reflect the products being illuminated and the visual result required by the project.

Leave a Reply

Your email address will not be published. Required fields are marked *

Facebook
Twitter
LinkedIn
Pinterest

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with the suffix “@br-lighting.com.cn”.